The remote mounted manifold configurations currently acceptable within the NAM-standard NSS are the following Astava model codes:
M5   M6   M8   M16  M17
These new configured models must also be applied in case of revamping or replacement of old instrument manifolds. To guide you from the "old" model codes to the new model codes an overview is given below. For more technical background on remote mounted manifolds please, click here (Pdf, 105 Kb).

Astava - the stopping power - remote mounted.Astava - the stopping power - remote mounted.

Model code M1
No longer applicable, obsolete. Superseded by M17.
Remote Flow, Level and dP (API 10,000):
4-valve Double Isolate / Equalise / Vent Remote Mounted Manifold in AISI316L acc. NACE, Viton/PTFE Packings, NPT process, test, vent and instrument ports with 3/8" / 10mm OD Gyrolok fittings, test connector with 1.5 mm orifice vent restriction, incl. tubing (vent/drain), all fittings and valves with locking pins.

Model code M2
No longer applicable, obsolete. Superseded by M16.
Remote Flow (Class 2500):
4-valve Double Isolate / Equalise / Vent Remote Mounted Manifold in AISI316L acc. NACE with DIN19213 / IEC61518 instrument interface, Viton/PTFE Packings, NPT process, test and vent ports with 3/8" / 10mm OD Gyrolok fittings, test connector with 1.5 mm orifice vent restriction, incl. tubing (vent/drain), all fittings and valves with locking pins.

Model code M3
No longer applicable, obsolete. Superseded by M16.
Remote Level (Class 2500):
4-valve Double Isolate / Double Vent Base Mounted Manifold in AISI316L acc. NACE with DIN19213 / IEC61518 instrument interface, Viton/PTFE Packing, NPT process, test and vent ports with 3/8" / 10mm OD Gyrolok fittings, test connector with 1.5 mm orifice vent restriction, incl. tubing (vent/drain), all fittings and valves with locking pins.

Model code M4
No longer applicable, obsolete. NAM does not apply Differential Pressure Transmitters at ASME Class 2500 without DIN19213 / IEC61518 Facing anymore.

Astava - the stopping power - remote mounted.Astava - the stopping power - remote mounted.

Model code M5
Remote Pressure (Class 2500):
2-valve Isolate/Vent Remote Mounted Pressure Manifold in AISI316L acc. NACE, Viton/PTFE Packings, NPT process, test/vent/drain and instrument ports with 3/8" / 10mm OD Gyrolok fittings, test connector with 1.5 mm orifice vent restriction, incl. tubing (vent/drain), all fittings and valves with locking pins.

 

Model code M6
Remote Pressure (Class 2500):
2-valve Isolate/Vent Remote Mounted Pressure Manifold in AISI316L acc. NACE with a half DIN19213 / IEC61518 instrument interface, Viton/PTFE Packing, NPT process and test/vent/drain ports with 3/8" / 10mm OD Gyrolok fittings, test connector with 1.5 mm orifice vent restriction, incl. tubing (vent/drain), all fittings and valves with locking pins.

Model code M7
No longer applicable, obsolete. Superseded by M16.
Remote Level (Class 600):
2-valve Isolate/Vent Base Remote Mounted Level Manifold in AISI316L acc. NACE with a full DIN19213 / IEC61518 instrument interface (with atmospheric port on LP side for atmospheric vessels), Viton/PTFE Packing, NPT process and test/vent/drain ports with 3/8" / 10mm OD Gyrolok fittings, test connector with 1.5 mm orifice vent restriction, incl. tubing (vent/drain), all fittings and valves with locking pins.

Model code M8
Remote Pressure (API 10,000):
2-valve Isolate/Vent Remote Mounted Pressure Manifold in AISI316L acc. NACE, Viton/PTFE Packing, NPT process, test/vent/drain and instrument ports with 3/8" / 10mm OD Gyrolok fittings, test connector with 1.5 mm orifice vent restriction, incl. tubing (vent/drain), all fittings and valves with locking pins, to be used for high pressure applications (>400 Barg).

Model code M16
Remote Flow, Level and dP (Class 2500):
5-valve Double Isolate / Equalise / Vent Remote Mounted Manifold in AISI316L acc. NACE with a full DIN19213/IEC61518 instrument interface, Viton/PTFE Packings, NPT process and test/vent/drain ports with 3/8" / 10mm OD Gyrolok fittings, test connector with 1.5 mm orifice vent restriction, incl. tubing (vent/drain), all fittings and valves with locking pins.

Model M17
Remote Flow, Level and dP (API 10,000):
5-valve Double Isolate / Equalise / Vent Remote Mounted Manifold in AISI316L acc. NACE, Viton/PTFE Packings, NPT process, test/vent/drain and Instrument ports with 3/8" / 10mm OD Gyrolok fittings, test connector with 1.5 mm orifice vent restriction, incl. tubing (vent/drain), all fittings and valves with locking pins.

For more model codes please click button Close coupled.

For more options please, contact This e-mail address is being protected from spambots. You need JavaScript enabled to view it
 

Astava - Oil and Gas

Astava - the stopping power - oil and gas.The market in which Astava is experienced for over 50 years with a wide range of products. Learn more...

Astava - (Petro) Chemical

Astava - the stopping power - (petro) chemical.For this industry Astava is partner for complete instrument hook-ups and accessories like sealpots, pulsation dampeners. Learn more...

Astava - Nuclear

Astava - the stopping power - nuclear (npp).Since the mid 70’s Astava is also active in the nuclear industry for the supply of solutions for Bellow Sealed valves and ASME valves. Learn more...
Pro Photo - webdesign